Business

Calidad en el laboratorio de ensayos

A 90-minute, 4-round basic Express simulation for Spanish vocational training (Formacion Profesional), Quimica family: module 0072 Calidad y seguridad en el laboratorio of the grado superior title Tecnico Superior en Laboratorio de Analisis y de Control de Calidad (Real Decreto 1395/2007).

4 rounds Undergraduate English, Español

Preview

About this simulation

A 90-minute, 4-round basic Express simulation for Spanish vocational training (Formacion Profesional), Quimica family: module 0072 Calidad y seguridad en el laboratorio of the grado superior title Tecnico Superior en Laboratorio de Analisis y de Control de Calidad (Real Decreto 1395/2007). English title: Lab Quality ISO 17025.

The learner is a newly qualified technician in the quality unit of a fictional water-testing laboratory accredited to UNE-EN ISO/IEC 17025 in an invented inland Spanish town, who follows the nitrate method by ion chromatography over four months (March to June 2028): a control chart with seven points in a row below the mean but within the limits, an unsatisfactory proficiency-test result, a nonconformity from the accreditation body's follow-up visit and a client's request about a result near the 50 mg/L parametric value.

Eight decisions over four moments: what to do about the trend and about the week's reports waiting for signature; how to answer the unsatisfactory z-score and how far back to review the reports already issued; how to answer the nonconformity and whether to extend it to chloride and sulphate; and the method's control plan and the report of a 51 mg/L result the client wants issued as conforming.

Scored on the erroneous reports left uncorrected at the end of June (shown by origin: January and February reports, the week of 6 March, March to June reports, other anions and other), the cost of quality, the mean report turnaround and the conformity with ISO/IEC 17025; one tempting choice hides its consequence until the intercomparison shows it (carrying on while the points are within limits), and two critical errors (re-analysing the proficiency-test sample with the assigned value known and filing it as the laboratory's result; issuing a changed result to suit the client) cap the card of their round.

Lesson: a trend is corrected before it becomes an erroneous result.

Training level only: stylised decision practice that complements module 0072 and supervised practice, and does not replace them; the figures are a stylised teaching model, not laboratory statistics, and no real decision can be taken from them; the technical director signs the reports, never the technician; the accreditation body's visit and its finding are fictional and nothing is said about how it actually decides; the method, the decision rule and the visit procedure are general knowledge that needs subject-expert review.

Spanish primary, English parity. All companies, places and people are fictional.

What participants learn

After the session, participants will be able to:

  • Apply the control chart to act on a trend while it is still inside the limits: stop, check with an independent standard and find the cause before it becomes an erroneous result
  • Analyze an unsatisfactory proficiency-test result as nonconforming work, looking for its cause in the raw data and the chart, and never re-analyse with the assigned value known
  • Evaluate the validity of results already issued with a look-back from when the problem began, re-testing the retained samples and telling the clients affected
  • Formulate the answer to an accreditation nonconformity with a root cause and a corrective-action plan extended to every method with the same practice
  • Apply an agreed decision rule to issue the measured result with its uncertainty, design the control plan by risk and never change a result to suit a client

Prerequisites

  • What a calibration curve, a control chart with ±2s limits and a proficiency-test z-score are
  • What accreditation to ISO/IEC 17025, nonconforming work and a corrective action are

Who it is for

An introductory simulation that assumes no prior knowledge of the subject, designed for undergraduate courses. It also works in vocational and high-school programmes and in onboarding sessions.

How a session runs

  1. The instructor creates a session from the Eureka dashboard and invites the participants.
  2. Participants play 4 rounds. In each one they submit their decisions and the simulation calculates the results. The first round opens with: Lunes 6 de marzo de 2028: siete puntos seguidos por debajo de la media en el gráfico de.
  3. The simulation can be run in English, Español.
  4. The instructor follows each participant's progress and results from the dashboard, and uses the class results for the debrief.

Decisions participants make

The decisions participants make during the simulation:

  • La tendencia del gráfico de control de nitratos
  • Los 38 informes de la semana pendientes de firma
  • El resultado insatisfactorio de la intercomparación
  • Los informes de nitratos ya emitidos
  • La no conformidad de la visita de ENAC
  • Los otros métodos del cromatógrafo
  • El plan de control de calidad del método desde junio
  • El informe de 51 mg/L que pide el consorcio

Ready to use Calidad en el laboratorio de ensayos with your students?

Contact us and we'll set you up with a free trial session.

Contact us