Maniobra en un centro de transformación
Maniobra en un centro de transformacion (Substation Switching).
A 90-minute, 4-round basic Express simulation for Spanish vocational training (Formacion Profesional), Quimica family: module 0072 Calidad y seguridad en el laboratorio of the grado superior title Tecnico Superior en Laboratorio de Analisis y de Control de Calidad (Real Decreto 1395/2007).
A 90-minute, 4-round basic Express simulation for Spanish vocational training (Formacion Profesional), Quimica family: module 0072 Calidad y seguridad en el laboratorio of the grado superior title Tecnico Superior en Laboratorio de Analisis y de Control de Calidad (Real Decreto 1395/2007). English title: Lab Quality ISO 17025.
The learner is a newly qualified technician in the quality unit of a fictional water-testing laboratory accredited to UNE-EN ISO/IEC 17025 in an invented inland Spanish town, who follows the nitrate method by ion chromatography over four months (March to June 2028): a control chart with seven points in a row below the mean but within the limits, an unsatisfactory proficiency-test result, a nonconformity from the accreditation body's follow-up visit and a client's request about a result near the 50 mg/L parametric value.
Eight decisions over four moments: what to do about the trend and about the week's reports waiting for signature; how to answer the unsatisfactory z-score and how far back to review the reports already issued; how to answer the nonconformity and whether to extend it to chloride and sulphate; and the method's control plan and the report of a 51 mg/L result the client wants issued as conforming.
Scored on the erroneous reports left uncorrected at the end of June (shown by origin: January and February reports, the week of 6 March, March to June reports, other anions and other), the cost of quality, the mean report turnaround and the conformity with ISO/IEC 17025; one tempting choice hides its consequence until the intercomparison shows it (carrying on while the points are within limits), and two critical errors (re-analysing the proficiency-test sample with the assigned value known and filing it as the laboratory's result; issuing a changed result to suit the client) cap the card of their round.
Lesson: a trend is corrected before it becomes an erroneous result.
Training level only: stylised decision practice that complements module 0072 and supervised practice, and does not replace them; the figures are a stylised teaching model, not laboratory statistics, and no real decision can be taken from them; the technical director signs the reports, never the technician; the accreditation body's visit and its finding are fictional and nothing is said about how it actually decides; the method, the decision rule and the visit procedure are general knowledge that needs subject-expert review.
Spanish primary, English parity. All companies, places and people are fictional.
Al terminar la sesión, los participantes serán capaces de:
Una simulación introductoria que no requiere conocimientos previos de la materia, pensada para asignaturas de grado. También funciona en formación profesional, bachillerato y sesiones de onboarding.
Las decisiones que toman los participantes durante la simulación:
Escríbenos y te preparamos una sesión de prueba gratuita.
Contactar