CrossTimezoneDecisions — Hard Calls When 40% of the Team Is Asleep
Design and run a 3-tier decision protocol (fast-track / async consensus / wait-for-overlap) for a team spread across 4 timezones.
A 90-minute, 4-round basic Express simulation for Spanish vocational training (Formacion Profesional), module 0976 Sistemas logicos de material rodante ferroviario of the Tecnico en Mantenimiento de Material Rodante Ferroviario (Real Decreto 1145/2012).
A 90-minute, 4-round basic Express simulation for Spanish vocational training (Formacion Profesional), module 0976 Sistemas logicos de material rodante ferroviario of the Tecnico en Mantenimiento de Material Rodante Ferroviario (Real Decreto 1145/2012).
The learner is Valerio Etxenagusia, a newly qualified rolling-stock maintenance technician on the door faults of the Navalcardena depot of a fictional regional railway operator, Trenes Somontejo.
Four situations set the depot's course in 2027: a door-closed lamp that flickers and traction lost, and how the unit is made safe before any door cover is opened (parking brake, wheels chocked, cab key withdrawn, movements blocked, the door's breaker locked out and tagged, the absence of voltage checked) and how the TCMS log is read (door by door, with the wiring diagram of the door loop and the traction interlock); a door loop that opens for a second, and how its open point is found (measured along the loop in halves, only the open part replaced) and the relays checked (tested against the diagram, the replacement bench-tested; a door taken out of service only with its own device); a door that will not lock, and how the limit switch and the lock are checked (against the maker's values) and how the unit goes back to service (a complete functional door test, traction refused with any door open, the unit held if any point fails); and the annual review of how each fault is reported (TCMS codes, root cause, serial numbers, the entity in charge of maintenance) and closed (thirty days of follow-up, repeated faults reviewed).
Bridging a safety to keep the timetable turns a fault into a risk.
Scored on the door faults right first time, the cost of the door-fault work, the hours of service lost per fault and the components replaced without need; training-level decision practice that complements the module's supervised practical work, the depot's procedures and the makers' manuals, with no voltage, resistance, adjustment value or procedure given.
Two critical errors cap the round at 40: the door cover opened live with the unit not protected (Real Decreto 614/2001; Real Decreto 1215/1997, Annex II, point 1.14), and the door loop bridged to send the unit out (Ley 31/1995, article 29.2.3; Decision 2011/291/EU, section 4.2.5.6). Spanish primary, English parity.
Al terminar la sesión, los participantes serán capaces de:
Una simulación introductoria que no requiere conocimientos previos de la materia, pensada para asignaturas de grado. También funciona en formación profesional, bachillerato y sesiones de onboarding.
Las decisiones que toman los participantes durante la simulación:
Escríbenos y te preparamos una sesión de prueba gratuita.
Contactar